{"endpoint":"https://www.qualityforeveryone.com/api/mcp","transport":"streamable-http","protocolVersion":"2024-11-05","auth":"public","tools":[{"id":"calculate-oee","name":"OEE Calculator","description":"Calculate Overall Equipment Effectiveness (Availability × Performance × Quality) and identify the largest loss category. When to use: Use when evaluating manufacturing line efficiency, machine utilization, or TPM/lean equipment losses.","inputSchema":{"type":"object","properties":{"planned":{"type":"number","description":"Planned production time (minutes, > 0)"},"run":{"type":"number","description":"Actual run time (minutes, > 0 and <= planned)"},"idealCycle":{"type":"number","description":"Ideal cycle time per unit (minutes, > 0)"},"total":{"type":"integer","description":"Total units produced (> 0)"},"good":{"type":"integer","description":"Good units produced (>= 0 and <= total)"}},"required":["planned","run","idealCycle","total","good"]}},{"id":"calculate-aql","name":"AQL Sampling Plan Calculator","description":"Compute ANSI/ASQ Z1.4 / ISO 2859-1 single-sampling acceptance plan (code letter, sample size, Ac, Re) for a given lot size, inspection level, and AQL. When to use: Use when planning incoming, in-process, or final lot acceptance inspection.","inputSchema":{"type":"object","properties":{"lot":{"type":"integer","description":"Lot size (>= 1)"},"level":{"type":"string","enum":["reduced","normal","heightened"],"description":"General inspection level (default: normal)"},"aql":{"type":"number","enum":[0.065,0.1,0.15,0.25,0.4,0.65,1,1.5,2.5,4,6.5],"description":"Acceptable Quality Limit (%)"}},"required":["lot","aql"]}},{"id":"calculate-grr","name":"Gage R&R Calculator","description":"Perform Measurement Systems Analysis (MSA) Gage R&R using the Average & Range method (2 appraisers, 2-10 parts, 2-3 trials) returning EV, AV, GRR, %TV, %Tolerance, and ndc. When to use: Use when validating measurement system repeatability and reproducibility.","inputSchema":{"type":"object","properties":{"readings":{"type":"array","description":"3D array readings[appraiser][part][trial] with 2 appraisers, 2-10 parts, 2-3 trials"},"tolerance":{"type":["number","null"],"description":"Optional specification tolerance width (USL - LSL)"}},"required":["readings"]}},{"id":"calculate-dpmo","name":"DPMO & Sigma Level Calculator","description":"Calculate Defects Per Opportunity (DPO), Defects Per Million Opportunities (DPMO), yield %, Z-score, and 1.5-sigma shifted Six Sigma level. When to use: Use when benchmarking defect rates or Six Sigma performance across processes.","inputSchema":{"type":"object","properties":{"defects":{"type":"integer","description":"Total defects observed (>= 0)"},"units":{"type":"integer","description":"Total units inspected (> 0)"},"opportunities":{"type":"integer","description":"Defect opportunities per unit (>= 1)"}},"required":["defects","units","opportunities"]}},{"id":"calculate-rty","name":"Rolled Throughput Yield (RTY) Calculator","description":"Calculate multi-step First Pass Yield (FPY) and Rolled Throughput Yield (RTY), identifying the weakest step and units lost per 1,000. When to use: Use when analyzing cumulative yield loss across a multi-stage production or service process.","inputSchema":{"type":"object","properties":{"yieldsPct":{"type":"array","items":{"type":"number"},"description":"Array of step First Pass Yield percentages (0..100)"}},"required":["yieldsPct"]}},{"id":"calculate-takt","name":"Takt Time Calculator","description":"Calculate customer Takt time, cycle-time gap, line capacity, and demand shortfall across time units (s, min, h, shift). When to use: Use when balancing assembly lines or matching production pace to customer demand.","inputSchema":{"type":"object","properties":{"available":{"type":"number","description":"Available production time (> 0)"},"availableUnit":{"type":"string","enum":["s","min","h","shift"],"description":"Unit for available time"},"demand":{"type":"number","description":"Customer demand in units (> 0)"},"cycle":{"type":["number","null"],"description":"Optional current cycle time (> 0)"},"cycleUnit":{"type":"string","enum":["s","min","h","shift"],"description":"Unit for cycle time"}},"required":["available","demand"]}},{"id":"calculate-mtbf","name":"MTBF, MTTR & Availability Calculator","description":"Calculate Mean Time Between Failures (MTBF), Mean Time To Repair (MTTR), and inherent availability. When to use: Use when analyzing equipment reliability, maintenance KPIs, or uptime SLAs.","inputSchema":{"type":"object","properties":{"operating":{"type":"number","description":"Total operating time (> 0)"},"failures":{"type":"integer","description":"Number of failures (>= 0)"},"repair":{"type":"number","description":"Total repair downtime (>= 0)"}},"required":["operating","failures","repair"]}},{"id":"calculate-capability","name":"Process Capability (Cp / Cpk) Calculator","description":"Compute Cp, Cpu, Cpl, Cpk, capability verdict band, sigma level, and expected PPM out-of-spec. When to use: Use when assessing whether a stable process meets engineering specification limits (USL/LSL).","inputSchema":{"type":"object","properties":{"usl":{"type":"number","description":"Upper Specification Limit"},"lsl":{"type":"number","description":"Lower Specification Limit (< USL)"},"mean":{"type":"number","description":"Process mean"},"sigma":{"type":"number","description":"Process standard deviation (> 0)"}},"required":["usl","lsl","mean","sigma"]}},{"id":"calculate-control","name":"X-bar & R Control Limits Calculator","description":"Calculate X-bar and R chart control limits (UCL/LCL) using standard A2, D3, D4 constants and optionally detect Western Electric out-of-control rules. When to use: Use when setting up Statistical Process Control (SPC) charts or checking subgroup means for instability.","inputSchema":{"type":"object","properties":{"n":{"type":"integer","description":"Subgroup size (2..10)"},"grandMean":{"type":"number","description":"Grand average (X-double-bar)"},"rBar":{"type":"number","description":"Average range (R-bar, > 0)"},"points":{"type":"array","items":{"type":"number"},"description":"Optional subgroup means to evaluate Western Electric rules 1-4"}},"required":["n","grandMean","rBar"]}},{"id":"calculate-copq","name":"Cost of Poor Quality (COPQ) Calculator","description":"Calculate total Cost of Quality / Poor Quality, percentage of revenue, failure-to-prevention ratio, and category shares. When to use: Use when quantifying financial impact of internal/external failures, appraisal, and prevention.","inputSchema":{"type":"object","properties":{"internal":{"type":"number","description":"Internal failure cost (>= 0)"},"external":{"type":"number","description":"External failure cost (>= 0)"},"appraisal":{"type":"number","description":"Appraisal cost (>= 0)"},"prevention":{"type":"number","description":"Prevention cost (>= 0)"},"revenue":{"type":"number","description":"Total revenue (> 0)"}},"required":["internal","external","appraisal","prevention","revenue"]}},{"id":"calculate-ppm","name":"Defect Rate & PPM Calculator","description":"Convert defective unit counts and total inspected units into Parts Per Million (PPM), percentage rate, and defects per 1,000. When to use: Use when reporting supplier quality PPM or lot defect rates.","inputSchema":{"type":"object","properties":{"defective":{"type":"integer","description":"Number of defective units (>= 0)"},"total":{"type":"integer","description":"Total units inspected (> 0)"}},"required":["defective","total"]}},{"id":"calculate-risk","name":"Risk Matrix & RPN Calculator","description":"Calculate S×O risk score and FMEA Risk Priority Number (RPN = S×O×D) on a 1-5 scale, flagging cases where high detection masks severe risk. When to use: Use when prioritizing FMEA failure modes or operational quality risks.","inputSchema":{"type":"object","properties":{"severity":{"type":"integer","description":"Severity rating (1..5)"},"occurrence":{"type":"integer","description":"Occurrence rating (1..5)"},"detection":{"type":"integer","description":"Detection rating (1..5)"}},"required":["severity","occurrence","detection"]}}]}