Protocolo A2A y MCP
API para desarrolladores e integración de agentes
Sin clave de API. Llame a Quality for Everyone mediante A2A JSON-RPC 2.0 o Model Context Protocol (MCP) para verificar certificados, consultar cursos y ejecutar 12 calculadoras de calidad.
A2A JSON-RPC 2.0
/api/a2a
POST / GET • 60 sol/min
Servidor MCP
/api/mcp
tools/list y tools/call
Tarjeta de agente
/.well-known/agent.json
JSON de descubrimiento A2A
Manifiesto LLM
/llms.txt
Guía en texto plano
Primera llamada en 5 minutos
Envíe una solicitud POST JSON-RPC 2.0 a /api/a2a o /api/mcp. Puede indicar la capacidad en params.metadata.skill, params.skill o directamente como method.
curl -sS -X POST https://www.qualityforeveryone.com/api/a2a \
-H "Content-Type: application/json" \
-d '{
"jsonrpc": "2.0",
"id": "first-call-1",
"method": "tasks/send",
"params": {
"metadata": { "skill": "calculate-oee" },
"input": {
"planned": 480,
"run": 456,
"idealCycle": 0.5,
"total": 850,
"good": 820
}
}
}'Habilidades y herramientas MCP registradas (16)
Las 12 calculadoras están disponibles tanto en /api/a2a como en /api/mcp.
| ID de habilidad / herramienta | Protocolo | Entradas requeridas | Descripción |
|---|---|---|---|
| verify-certificate | A2A | code (cadena, p. ej. QFE-7X9B-2M4L-8K1P) | Valida una credencial de Quality for Everyone por código. Los apellidos se muestran enmascarados. |
| list-courses | A2A | Ninguna | Enumera todos los cursos publicados de la Academia sin borradores ni claves de examen. |
| get-course | A2A | slug o id | Obtiene metadatos del curso y el esquema publicado de lecciones de un curso concreto. |
| get-lesson | A2A | id o slug | Obtiene el material de lectura de una lección publicada dentro de un curso publicado. |
| calculate-oee | A2A + MCP | planned, run, idealCycle, total, good | Calculate Overall Equipment Effectiveness (Availability × Performance × Quality) and identify the largest loss category. When to use: Use when evaluating manufacturing line efficiency, machine utilization, or TPM/lean equipment losses. |
| calculate-aql | A2A + MCP | lot, aql | Compute ANSI/ASQ Z1.4 / ISO 2859-1 single-sampling acceptance plan (code letter, sample size, Ac, Re) for a given lot size, inspection level, and AQL. When to use: Use when planning incoming, in-process, or final lot acceptance inspection. |
| calculate-grr | A2A + MCP | readings | Perform Measurement Systems Analysis (MSA) Gage R&R using the Average & Range method (2 appraisers, 2-10 parts, 2-3 trials) returning EV, AV, GRR, %TV, %Tolerance, and ndc. When to use: Use when validating measurement system repeatability and reproducibility. |
| calculate-dpmo | A2A + MCP | defects, units, opportunities | Calculate Defects Per Opportunity (DPO), Defects Per Million Opportunities (DPMO), yield %, Z-score, and 1.5-sigma shifted Six Sigma level. When to use: Use when benchmarking defect rates or Six Sigma performance across processes. |
| calculate-rty | A2A + MCP | yieldsPct | Calculate multi-step First Pass Yield (FPY) and Rolled Throughput Yield (RTY), identifying the weakest step and units lost per 1,000. When to use: Use when analyzing cumulative yield loss across a multi-stage production or service process. |
| calculate-takt | A2A + MCP | available, demand | Calculate customer Takt time, cycle-time gap, line capacity, and demand shortfall across time units (s, min, h, shift). When to use: Use when balancing assembly lines or matching production pace to customer demand. |
| calculate-mtbf | A2A + MCP | operating, failures, repair | Calculate Mean Time Between Failures (MTBF), Mean Time To Repair (MTTR), and inherent availability. When to use: Use when analyzing equipment reliability, maintenance KPIs, or uptime SLAs. |
| calculate-capability | A2A + MCP | usl, lsl, mean, sigma | Compute Cp, Cpu, Cpl, Cpk, capability verdict band, sigma level, and expected PPM out-of-spec. When to use: Use when assessing whether a stable process meets engineering specification limits (USL/LSL). |
| calculate-control | A2A + MCP | n, grandMean, rBar | Calculate X-bar and R chart control limits (UCL/LCL) using standard A2, D3, D4 constants and optionally detect Western Electric out-of-control rules. When to use: Use when setting up Statistical Process Control (SPC) charts or checking subgroup means for instability. |
| calculate-copq | A2A + MCP | internal, external, appraisal, prevention, revenue | Calculate total Cost of Quality / Poor Quality, percentage of revenue, failure-to-prevention ratio, and category shares. When to use: Use when quantifying financial impact of internal/external failures, appraisal, and prevention. |
| calculate-ppm | A2A + MCP | defective, total | Convert defective unit counts and total inspected units into Parts Per Million (PPM), percentage rate, and defects per 1,000. When to use: Use when reporting supplier quality PPM or lot defect rates. |
| calculate-risk | A2A + MCP | severity, occurrence, detection | Calculate S×O risk score and FMEA Risk Priority Number (RPN = S×O×D) on a 1-5 scale, flagging cases where high detection masks severe risk. When to use: Use when prioritizing FMEA failure modes or operational quality risks. |