Protocollo A2A e MCP
API per sviluppatori e integrazione agenti
Nessuna chiave API richiesta. Chiama Quality for Everyone tramite A2A JSON-RPC 2.0 o Model Context Protocol (MCP) per verifica certificati, catalogo corsi e 12 calcolatori.
A2A JSON-RPC 2.0
/api/a2a
POST / GET • 60 rich/min
Server strumenti MCP
/api/mcp
tools/list e tools/call
Scheda agente
/.well-known/agent.json
JSON di scoperta A2A
Manifesto LLM
/llms.txt
Guida testuale per agenti
Prima chiamata in 5 minuti
Invia una richiesta POST JSON-RPC 2.0 a /api/a2a o /api/mcp. Passa la skill in params.metadata.skill, params.skill o direttamente come method.
curl -sS -X POST https://www.qualityforeveryone.com/api/a2a \
-H "Content-Type: application/json" \
-d '{
"jsonrpc": "2.0",
"id": "first-call-1",
"method": "tasks/send",
"params": {
"metadata": { "skill": "calculate-oee" },
"input": {
"planned": 480,
"run": 456,
"idealCycle": 0.5,
"total": 850,
"good": 820
}
}
}'Competenze e strumenti MCP registrati (16)
Tutti i 12 calcolatori sono disponibili sia su /api/a2a che su /api/mcp.
| ID competenza / strumento | Protocollo | Input richiesti | Descrizione |
|---|---|---|---|
| verify-certificate | A2A | code (stringa, es. QFE-7X9B-2M4L-8K1P) | Convalida una credenziale Quality for Everyone tramite codice. I cognomi sono mascherati. |
| list-courses | A2A | Nessuno | Elenca tutti i corsi pubblici dell’Academy senza bozze o risposte d’esame. |
| get-course | A2A | slug o id | Recupera metadati del corso e indice delle lezioni pubblicate per un corso specifico. |
| get-lesson | A2A | id o slug | Recupera il materiale didattico di una lezione pubblicata in un corso pubblico. |
| calculate-oee | A2A + MCP | planned, run, idealCycle, total, good | Calculate Overall Equipment Effectiveness (Availability × Performance × Quality) and identify the largest loss category. When to use: Use when evaluating manufacturing line efficiency, machine utilization, or TPM/lean equipment losses. |
| calculate-aql | A2A + MCP | lot, aql | Compute ANSI/ASQ Z1.4 / ISO 2859-1 single-sampling acceptance plan (code letter, sample size, Ac, Re) for a given lot size, inspection level, and AQL. When to use: Use when planning incoming, in-process, or final lot acceptance inspection. |
| calculate-grr | A2A + MCP | readings | Perform Measurement Systems Analysis (MSA) Gage R&R using the Average & Range method (2 appraisers, 2-10 parts, 2-3 trials) returning EV, AV, GRR, %TV, %Tolerance, and ndc. When to use: Use when validating measurement system repeatability and reproducibility. |
| calculate-dpmo | A2A + MCP | defects, units, opportunities | Calculate Defects Per Opportunity (DPO), Defects Per Million Opportunities (DPMO), yield %, Z-score, and 1.5-sigma shifted Six Sigma level. When to use: Use when benchmarking defect rates or Six Sigma performance across processes. |
| calculate-rty | A2A + MCP | yieldsPct | Calculate multi-step First Pass Yield (FPY) and Rolled Throughput Yield (RTY), identifying the weakest step and units lost per 1,000. When to use: Use when analyzing cumulative yield loss across a multi-stage production or service process. |
| calculate-takt | A2A + MCP | available, demand | Calculate customer Takt time, cycle-time gap, line capacity, and demand shortfall across time units (s, min, h, shift). When to use: Use when balancing assembly lines or matching production pace to customer demand. |
| calculate-mtbf | A2A + MCP | operating, failures, repair | Calculate Mean Time Between Failures (MTBF), Mean Time To Repair (MTTR), and inherent availability. When to use: Use when analyzing equipment reliability, maintenance KPIs, or uptime SLAs. |
| calculate-capability | A2A + MCP | usl, lsl, mean, sigma | Compute Cp, Cpu, Cpl, Cpk, capability verdict band, sigma level, and expected PPM out-of-spec. When to use: Use when assessing whether a stable process meets engineering specification limits (USL/LSL). |
| calculate-control | A2A + MCP | n, grandMean, rBar | Calculate X-bar and R chart control limits (UCL/LCL) using standard A2, D3, D4 constants and optionally detect Western Electric out-of-control rules. When to use: Use when setting up Statistical Process Control (SPC) charts or checking subgroup means for instability. |
| calculate-copq | A2A + MCP | internal, external, appraisal, prevention, revenue | Calculate total Cost of Quality / Poor Quality, percentage of revenue, failure-to-prevention ratio, and category shares. When to use: Use when quantifying financial impact of internal/external failures, appraisal, and prevention. |
| calculate-ppm | A2A + MCP | defective, total | Convert defective unit counts and total inspected units into Parts Per Million (PPM), percentage rate, and defects per 1,000. When to use: Use when reporting supplier quality PPM or lot defect rates. |
| calculate-risk | A2A + MCP | severity, occurrence, detection | Calculate S×O risk score and FMEA Risk Priority Number (RPN = S×O×D) on a 1-5 scale, flagging cases where high detection masks severe risk. When to use: Use when prioritizing FMEA failure modes or operational quality risks. |